Mechanical Systems Expert

Posted yesterday

hut8Corpus Christi (TX)

SENIORITY

Senior

Apply

About the role

ABOUT THE ROLE: The Mechanical Systems Expert is Managed Services' expert embedded in a data center build - supporting design review and commissioning to ensure cooling systems are operable and maintainable at turnover. Every design decision eventually becomes someone's 3 a.m. problem; this role reviews the design and witnesses the testing on behalf of that person. Some of the key responsibilities you should expect are the following: Operability Design ReviewReview mechanical and cooling designs - chilled water plants, air and liquid cooling systems, CDUs, CRAHs, heat rejection, water treatment - through an operations lens: maintenance access and laydown, isolation and redundancy behavior, degraded-mode operation, instrumentation adequacy, and failure-mode consequences. File review comments that change designs, not just document concerns. Construction-Phase VerificationWalk mechanical installations at key milestones: pipe routing and support, valve access, equipment clearances, insulation quality, and cleanliness/flushing protocol compliance - catching operability problems while they're still cheap to fix. Commissioning WitnessWitness Level 3-5 commissioning of mechanical systems: functional performance tests, staging and failover sequences, failure scenarios, and integrated systems testing. Drive operational issues into the Cx log with clear acceptance criteria and verify closure personally. Turnover ReadinessVerify mechanical turnover packages: O&M, as-builts, valve tags and system labeling, water treatment baselines, spare parts and consumables lists, and PM program inputs (frequencies, procedures, vendor contacts). Validate training actually equips operators to run the plant. Operations Transition SupportSupport early operations stabilization post-turnover: alarm tuning input, setpoint refinement, and first-months troubleshooting alongside the operations team. Program FeedbackFeed operational lessons into Hut 8 mechanical design standards and the next project's basis of design.
ABOUT YOU
What we're looking for: 8+ years in critical facilities mechanical operations, commissioning, or chief-engineer-track roles. Deep hands-on knowledge of chilled water plants, hydronic systems, and data center cooling topologies - air-cooled, water-cooled, and liquid/direct-to-chip. Level 1-5 commissioning fluency from the witness/operations side, including integrated systems testing. Sharp eye for maintainability in design reviews: access, isolation, and instrumentation gaps. Turnover documentation rigor - you read the O&M before signing for it. Comfortable embedded with a construction team while holding the operations line. Water treatment and cleanliness protocol experience for critical hydronic systems. CFC/EPA certifications, trade licensure, or engineering degree all welcome paths. ABOUT THE WORK ENVIRONMENTFull time on-site role.

Before you apply

Applying takes about a minute. These four things decide how fast it moves after that.

Your profile is current

It's what we read first. Occupations, seniority and locations matter more than a long history.

Two examples you can talk through

Not a portfolio — just two pieces of work where you can explain the decisions and what you'd change.

A number in mind

What you're on now and what would make you move. We negotiate better when we know both.

Your notice period

Employers plan around it, and it's the question that stalls offers most often.

Once you apply, someone reads it and calls you before anything reaches the employer — usually within two working days.

More like this